
NFPA 72 National Fire Alarm and Signaling Code Handbook 2019 Edition
Product Code/ISBN: 72HB19
$323.95
The newest edition of the NFPA 72 and all the codes and standards associated with it.
Table of Contents
- Administration
- Scope
- Purpose
- Application
- Units and Formulas
- Code Adoption Requirements
- Referenced Publications
- General
- NFPA Publications
- Other Publications
- References for Extracts in Mandatory Sections
- Definitions
- General
- NFPA Official Definitions
- General Definitions
- Reserved
- Reserved
- Reserved
- Documentation
- Application (SIG-FUN)
- Minimum Required Documentation (SIG-FUN)
- Design (Layout) Documentation
- Shop Drawings (Installation Documentation) (SIG-FUN)
- Completion Documentation
- Inspection, Testing, and Maintenance Documentation (SIG-TMS)
- Records, Record Retention, and Record Maintenance
- Forms
- Reserved
- Reserved
- Fundamentals
- Application
- Purpose
- Equipment
- Design and Installation
- Personnel Qualifications
- Power Supplies
- Signal Priority
- Detection and Signaling Conditions
- Responses
- Distinctive Signals
- Alarm Signals
- Fire Alarm Notification Appliance Deactivation
- Carbon Monoxide (CO) Notification Appliance Deactivation
- Supervisory Signals
- Trouble Signals
- Emergency Control Function Status Indicators
- Notification Appliance Circuits and Control Circuits
- Annunciation and Annunciation Zoning
- Monitoring Integrity of In-Building Fire Emergency Voice/Alarm Communication Systems
- Documentation and Notification
- Impairments
- Unwanted Alarms
- Reserved
- Circuits and Pathways
- Applications
- General
- Pathway Class Designations
- Pathway Survivability
- Shared Pathway Designations
- Monitoring Integrity and Circuit Performance of Installation Conductors and other Signaling Channels
- Nomenclature
- Reserved
- Inspection, Testing, and Maintenance
- Application
- General
- Inspection
- Testing
- Maintenance
- Records
- Reserved
- Reserved
- Initiating Devices
- Application
- Purpose
- Performance-Based Design
- General Requirements
- Requirements for Smoke and Heat Detectors
- Heat-Sensing Fire Detectors
- Smoke-Sensing Fire Detectors
- Radiant Energy-Sensing Fire Detectors
- Combination, Multi-Criteria, and Multi-Sensor Detectors
- Gas Detection
- Other Fire Detectors
- Carbon Monoxide Detectors
- Sprinkler Waterflow Alarm-Initiating Devices
- Detection of Operation of Other Automatic Extinguishing Systems
- Manual Actuated Alarm-Initiating Devices
- Fire Extinguisher Electronic Monitoring Device
- Supervisory Signal-Initiating Devices
- Notification Appliances
- Application
- Purpose
- General
- Audible Characteristics
- Visual Characteristics – Public Mode
- Visual Characteristics – Private Mode
- Supplementary Visual Signaling Method
- Textual Audible Appliances
- Textual and Graphical Visual Appliances
- Tactile Appliances
- Standard Emergency Service Interface
- Reserved
- Reserved
- Emergency Control Function Interfaces
- Application
- General
- Elevator Phase I Emergency Recall Operation
- Elevator Power Shutdown
- Fire Service Access Elevators
- Occupant Evacuation Elevators (OEE)
- Heating, Ventilating and Air-Conditioning (HVAC) Systems
- High Volume Low Speed (HVLS) Fans
- Door and Shutter Release
- Electrically Locked Doors
- Exit Marking Audible Notification Systems
- Reserved
- Protected Premises Alarm and Signaling Systems
- Application
- General
- System Features
- System performance and Integrity
- Performance of Initiating Device Circuits (IDCs)
- Performance of Signaling Line Circuits (SLCs)
- Performance of Notification Appliance Circuits (NACs)
- Systems Requirements
- In-Building Emergency Voice/Alarm Communications
- Fire Alarm Systems Using Tone
- Suppression System Actuation
- Off-Premises Signals
- Guard’s Tour Supervisory Service
- Suppressed (exception Reporting) Signal System
- Protected Premises Emergency Control Function
- Special Requirements for Low-Power Radio (Wireless) Systems
- Emergency Communications Systems (ECS)
- Application
- Purpose
- General
- In-Building Fire Emergency Voice/Alarm Communications Systems (EVACS)
- In-Building Mass Notification Systems
- Wide-Area Mass Notification Systems
- Distributed Recipient Mass Notification Systems (DRMNS)
- Two-Way, In-Building Wired Emergency Services Communications Systems
- Two-Way Radio Communications Enhancement Systems
- Area of Refuge (Area of Rescue Assistance) Emergency Communications Systems, Stairway Communication Systems, Elevator Landing Communications Systems, and occupant Evacuation Elevator Lobby Communications Systems
- Information, Command, and Control
- Performance-Based Design of Mass Notifications Systems
- Documentation for Emergency Communications Systems
- Reserved
- Supervising Station Alarm Systems
- Application
- General
- Central Station Service Alarm Systems
- Proprietary Supervising Station Alarm Systems
- Remote Supervising Station Alarm Systems
- Communications Methods for Supervising Station Alarm Systems
- Public Emergency Alarm Reporting Systems
- Applications
- General
- Management and Maintenance
- Communications Methods
- Alarm Processing Equipment
- Alarm Boxes
- Public Cable Plant
- Emergency Communications Systems (ECS)
- Reserved
- Single- and Multiple-Station Alarms and Household Signaling Systems
- Application
- Purpose
- Basic Requirements
- Remote Annunciation
- Notification
- Assumptions
- Carbon Monoxide Detection
- Detection and Notification
- Power Supplies
- Equipment Performance
- Installation
- Optional Function
- Inspection, Testing, and Maintenance
- Markings and Instructions
- Annexes
- Explanatory Material
- Engineering Guide for Automatic Fire detector Spacing
- System Performance and Design Guide
- Speech Intelligibility
- Sample Ordinance Adopting NFPA 72
- Wiring Diagrams and Guide for Testing Fire Alarm Circuits
- Guidelines for Emergency Communication Strategies for Buildings and Campuses
- Carbon Monoxide
- Informational References